AUX AC Error Codes for 2021 Models

No. Failure Code Failure Name Primary Troubleshooting Parts
1 L0 DC Over/Under-voltage Failure The outdoor unit controller / the power grid
2 L1 Overcurrent Protection on Phase Current The outdoor unit controller / the power grid /
of The compressor the compressor/the compressor wire
3 L2 Step Failure of The compressor The outdoor unit controller / the power grid /
the compressor/system pressure
4 L3 Phase Failure of The compressor The outdoor unit controller / the power grid /
the compressor/the compressor wire
5 L4 Driver Module IPM Failure of The compressor The outdoor unit controller / the power grid /
the compressor
6 L5 PFC Overcurrent Hardware Protection The outdoor unit controller / the power grid
7 L6 PFC Overcurrent Software Protection The outdoor unit controller / the power grid
8 L7 AD Abnormal Protection in Current The outdoor unit controller
Detection
9 L8 Shunt Resistance Imbalance Failure The outdoor unit controller
10 L9 IPM Temperature Sensor Failure The outdoor unit controller
11 LA The compressor Startup Failure The outdoor unit controller / the power grid /
the compressor/the compressor wire
12 LC AD Abnormal Protection in PFC Current The outdoor unit controller
Detection

 

 

Display the error code of the indoor unit: fix speed A/C & E1.  E2, E3 and E4 Errors

No. Error Code Error Name Probable Trouble Location
1 E1 Internal room temperature The internal room temperature sensor, the main internal
sensor error control panel
2 E2 External coil sensor error External coil sensor error, the main external control
panel
3 E3 Internal coil sensor error Internal coil sensor error, the main internal control
panel
4 E4 The indoor fan error Mechanical jam of internal the fan blade, internal fan,
the main internal control panel
5 E5(5E) The indoor and outdoor unit The bridge cable, the main internal control panel, the main
communication error external control panel, module panel
6 F0 The outdoor DC fan error Mechanical jam of external the fan, external DC of the fan,
the main external control panel
7 F1 Module protection error The power voltage, the compressor cable, the reactor, the module
the panel, the main external control panel, the compressor
8 F2 PFC protection error The power voltage, reactor, module panel, the main
external control panel
9 F3 The compressor out-of-step System pressure, the compressor cable, module panel,
error the main external control panel, the compressor
10 F4 Exhaust air sensor error Exhaust air sensor, the main external control panel
11 F5 The compressor cap sensor error System pressure, the compressor cap sensor
(Protection switch), the main external control panel
12 F6 External room temperature The external room temperature sensor, the main external
sensor error control panel
13 F7 OVP or UVP error The power voltage, reactor, module panel, the main
external control panel
The main external control panel Connection wire of module and the main control data,
14 F8 and module panel
module panel, the main external control panel
communication error
15 F9 The outdoor EE error The main external control panel
16 FA Recirculated sensor error The recirculated sensor, the four-way valve, and the main external
control panel

 

 