(CX(G)AV 085 / 150
Cooling: 85~1700kW / 150~3000kW
Heating: 85~1700kW / 150~3000kW 50 / 60Hz)
M01 Module outgoing water temperature sensor problem
M02 Module return water temperature sensor problem
E15 Customer pump is not ready
C00 Communication with the Module Controller failed to Stop the device
C10 Communication with OD Controller failed to Stop the device
F01 Inlet water temperature sensor problem
F03 Intermediate water temperature sensor problem
F02 Outlet water temperature sensor problem
F10 Ambient temperature sensor problem
LLWT Cooling anti-freeze alarm
E12 Pump driver problem
E11 Pump overload alarm Stop the unit
E10 Flow switch alarm
E14 Customer pump is not ready (unit) Stop the unit
C05 Communication error between OD Controller and pump Stop the unit
C01 Communication error between OD Controller and circuit Stop the unit
F11A High-pressure sensor problem
F12A Low-pressure sensor problem
F06A Ejection temperature sensor problem
F07A Intake temperature sensor problem
F08A Coil gas temperature sensor 1 problem
F09A Coil gas temperature sensor 2 problem
E04A Ejection temperature abnormality lock
E05A High-pressure abnormality lock
E06A Low-pressure abnormality lock
E13A High-pressure switch trigger
E07A Cooler LRTC lock
E36A Compressor mains power abnormal
E08A Compressor start-up abnormal
CP01 Compressor problem
FD01 Fan motor problem
C02A Communication problem between Circuit Controller and compressor
C03A Communication problem between Circuit Controller and fan
F11B High-pressure sensor problem
146 CG-SVX026A-JA Control Operations
F12B Low-pressure sensor problem
F06B Ejection temperature sensor problem
F07B Intake temperature sensor problem
F08B Coil gas temperature sensor 1 problem
E04B Ejection temperature abnormal
E05B High-pressure abnormality lock
E06B Low-pressure abnormality lock
E13B High-pressure switch trigger
E07B Cooler LRTC lock
E36B Compressor mains power abnormality
E08B Compressor start-up abnormality
CP02 Compressor problem
FD02 Fan motor problem
C02B Communication problem between Circuit Controller and compressor
C03B Communication problem between Circuit Controller and fan
F11C High-pressure sensor problem
F12C Low-pressure sensor problem
F06C Ejection temperature sensor problem
F07C Intake temperature sensor problem
F08C Coil gas temperature sensor 1 problem
F09C Coil gas temperature sensor 2 problem
E04C Ejection temperature abnormality lock
E05C High-pressure abnormality lock
E06C Low-pressure abnormality lock
E13C High-pressure switch trigger
E07C Cooler LRTC lock
E36C Compressor mains power abnormal
E08C Compressor start-up abnormal
CP03 Compressor problem
FD03 Fan motor problem
C02C Communication error between Circuit Controller and compressor
C03C Communication error between Circuit Controller and fan
F11D High-pressure sensor problem
F12D Low-pressure sensor error
F06D Ejection temperature sensor problem
F07D Intake temperature sensor problem
F08D Coil gas temperature sensor 1 problem
F09D Coil gas temperature sensor 2 problem
E04D Ejection temperature abnormality lock
E05D High-pressure abnormality lock
E06D Low-pressure abnormality lock
E13D High-pressure switch trigger
E07D Cooler LRTC lock
E36D Compressor mains power abnormality
E08D Compressor start-up abnormality
CP04 Compressor problem
FD04 Fan motor problem
C02D Communication error between Circuit Controller and compressor
C03D Communication error between Circuit Controller and fan